Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
1.
PLoS One ; 19(4): e0302321, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635729

RESUMO

AIMS: This study investigated whether an activated R-mode in patients carrying a cardiac implantable electronic device (CIED) is associated with worse prognosis during and after an episode of acutely decompensated heart failure (AHF). METHODS: Six hundred and twenty-three patients participating in an ongoing prospective cohort study that phenotypes and follows patients admitted for AHF were studied. We compared CIED carriers with activated R-mode stimulation (CIED-R) to CIED carriers not in R-mode (CIED-0) and patients without CIEDs (no-CIED). The independent impact of R-mode activation on 12-month all-cause death was examined using uni- and multivariable Cox proportional hazards regression taking into account potential confounders, and hazard ratios (HR) with their 95% confidence intervals (CI) were reported. RESULTS: Mean heart rate on admission was lower in CIED-R (n = 37, 16% women) vs. CIED-0 (n = 64, 23% women) or no-CIED (n = 511, 43% women): 70 bpm vs. 80 bpm or 82 bpm; both p<0.001. In-hospital mortality was similar across groups, but age- and sex-adjusted all-cause 12-month mortality risk was differentially affected by R-mode activation; CIED-R vs. CIED-0: HR 2.44, 95%CI 1.25-4.74; CIED-R vs. no-CIED: HR 2.61, 95%CI 1.59-4.29. These effects persisted after multivariable adjustment for potential confounders. Within CIED-R, mortality risk was similar in patients with pacemakers vs. ICDs and in subgroups with left ventricular ejection fraction (LVEF) <50% vs. ≥50%. CONCLUSION: In patients admitted with AHF, R-mode stimulation was associated with a significantly increased 12-month mortality risk. Our findings shed new light on "admission heart rate" as a potentially treatable target in AHF. Our data are compatible with the concept that chronotropic incompetence contributes to an adverse outcome in these patients and may not be adequately treated through accelerometer-based R-mode stimulation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Feminino , Masculino , Volume Sistólico , Estudos Prospectivos , Função Ventricular Esquerda , Estudos Retrospectivos
2.
Tomography ; 10(2): 255-265, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38393288

RESUMO

This study investigated the efficacy of single-phase dual-energy CT (DECT) in differentiating pulmonary hamartomas from malignant lung lesions using virtual non-contrast (VNC), iodine, and fat quantification. Forty-six patients with 47 pulmonary lesions (mean age: 65.2 ± 12.1 years; hamartomas-to-malignant lesions = 22:25; male: 67%) underwent portal venous DECT using histology, PET-CT and follow-up CTs as a reference. Quantitative parameters such as VNC, fat fraction, iodine density and CT mixed values were statistically analyzed. Significant differences were found in fat fractions (hamartomas: 48.9%; malignancies: 22.9%; p ≤ 0.0001) and VNC HU values (hamartomas: -20.5 HU; malignancies: 17.8 HU; p ≤ 0.0001), with hamartomas having higher fat content and lower VNC HU values than malignancies. CT mixed values also differed significantly (p ≤ 0.0001), but iodine density showed no significant differences. ROC analysis favored the fat fraction (AUC = 96.4%; sensitivity: 100%) over the VNC, CT mixed value and iodine density for differentiation. The study concludes that the DECT-based fat fraction is superior to the single-energy CT in differentiating between incidental pulmonary hamartomas and malignant lesions, while post-contrast iodine density is ineffective for differentiation.


Assuntos
Hamartoma , Iodo , Neoplasias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Hamartoma/diagnóstico por imagem
3.
Tech Vasc Interv Radiol ; 26(3): 100914, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38071023

RESUMO

Magnetic resonance (MR) image guidance has demonstrated significant potential in the field of interventional radiology in several applications. This article covers the main points of MR-guided hepatic tumor ablation as a representative of MR-guided procedures. Patient selection and appropriate equipment utilization are essential for successful MR-guided tumor ablation. Intra-procedural planning imaging enables the visualization of the tumor and surrounding anatomical structures in most cases without the application of a contrast agent, ensuring optimal planning of the applicator tract. MRI enables real-time, multiplanar imaging, thus simultaneous observation of the applicator and target tumor is possible during targeting with adaptable slice angulations in case of challenging tumor positions. Typical ablation zone appearance during therapy monitoring with MRI enables safe assessment of the therapy result, resulting in a high primary efficacy rate. Recent advancements in ablation probes have shortened treatment times, while technical strategies address applicator visibility issues. MR-imaging immediately after the procedure is used to rule out complications and to assess technical success. Especially in smaller neoplasms, MRI-guided liver ablation demonstrates positive outcomes in terms of technical success rates, as well as promising survival and recurrence rates. Additionally, percutaneous biopsy under MR guidance offers an alternative to classic guidance modalities, providing high soft tissue contrast and thereby increasing the reliability of lesion detection, particularly in cases involving smaller lesions. Despite these advantages, the use of MR guidance in clinical routine is still limited to few indications and centers, due to by high costs, extended duration, and the need for specialized expertise. In conclusion, MRI-guided interventions could benefit from ongoing advancements in hardware, software, and devices. Such progress has the potential to expand diagnostic and treatment options in the field of interventional radiology.


Assuntos
Neoplasias Hepáticas , Imagem por Ressonância Magnética Intervencionista , Humanos , Consenso , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia
4.
Res Sports Med ; 31(2): 112-124, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34176387

RESUMO

The aim was to investigate side-to-side and sex differences of anterior and inferior capsule thickness (ACT, ICT) between the throwing and non-throwing shoulder (TS, NTS) in youth elite handball players. 125 youth female and male elite handball players (14.1±0.7yo) were assessed for ACT and ICT by ultrasound . ACT measurement was performed from anterior (3 o'clock) in upright position and for ICT from inferior (6 o'clock) in supine position. Measurements of ICT in the TS of all athletes (1.4±0.2 mm) differed significantly but marginally to those in the NTS (1.3±0.2 mm) (p = 0.001). Female (1.2±0.2 mm vs. 1.3±0.2 mm; p = 0.007) but not male youth players (1.4±0.2 mm vs. 1.4±0.2 mm, p = n.s.) demonstrated slight differences in ICT in the TS compared with the NTS. Although significant, the thickness in the TS compared to the NTS was within the measurement accuracy of the ultrasonic assessment. No difference in ACT was observed in the TS (1.4±0.3 mm) compared to the NTS (1.4±0.3 mm) for both sexes (n.s.).In conclusion, the anterior and inferior capsule thickness in youth elite handball athletes is not or only marginally different between throwing and non-throwing shoulders.


Assuntos
Articulação do Ombro , Esportes , Humanos , Masculino , Feminino , Adolescente , Amplitude de Movimento Articular , Articulação do Ombro/diagnóstico por imagem , Atletas , Ultrassonografia
5.
Eur Radiol ; 33(4): 2415-2425, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36350390

RESUMO

OBJECTIVE: Subjective and objective image quality comparison of bone microstructure and disease-related abnormalities in multiple myeloma patients using a 1st-generation dual-source photon-counting detector CT(DS-PCD-CT) and a 2nd-generation dual-source dual-energy (energy-integrating detector) CT (DS-EID-CT). METHODS: Fifty multiple myeloma patients (mean age 67.7 ± 10.9 years,16 females) were prospectively enrolled. Unenhanced whole-body CTs were clinically indicated and performed on DS-EID-CT and DS-PCD-CT (median time difference: 12 months). DS-PCD-CT was performed in Quantumplus UHR mode and DS-EID-CT was performed using dual-energy mode. DS-PCD-CT kernel was set at Br64 with Quantum iterative reconstruction strength Q1; for DS-EID-CT a comparable I70f kernel with SAFIRE iterative reconstruction strength 1 was used. Two independent radiologists assessed image quality subjectively using a 5-point Likert scale considering delineation and sharpness of trabecular bone and lytic bone lesions in the spine and pelvic bones. Additionally, ImageJ was used for quantification of bony septa inside the cancellous bone and through or the edges of osteolysis. RESULTS: Overall quality as well as detectability and sharpness in the delineation of lytic bone lesions were superior for DS-PCD-CT compared with DS-EID-CT (p < 0.0001). The inter-reader agreement for subjective image quality readings showed excellent consistency(α = 94.2-98.8). CTDI and DLP mean values for DS-PCD-CT and DS-EID-CT were 1107.4 ± 247.6 mGy*cm and 8.2 ± 1.8 mGy vs. 1344.3 ± 204.6 mGy*cm and 10.1 ± 1.9 mGy. The quantitative metric for bone microstructure in the femoral head showed significantly better visualization of trabeculae in DS-PCD-CT compared with DS-EID-CT (p < 0.0001). Quantitative analyses of edge sharpness of osteolysis showed significant steeper edges for DS-PCD-CT (p < 0.0001). CONCLUSION: DS-PCD-CT significantly improves spatial resolution of bony microstructure and lytic bone lesions compared to DS-EID-CT. KEY POINTS: • Application of photon-counting detector CT is superior to dual-source dual-energy integrating detector in clinical workup of multiple myeloma patients. • Compared to energy integrating detectors, photon-counting detectors significantly increase the spatial resolution of bone microstructure including disease-related lytic bone lesions in patients with multiple myeloma.


Assuntos
Mieloma Múltiplo , Osteólise , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Mieloma Múltiplo/diagnóstico por imagem , Osteólise/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Fótons
6.
Diagnostics (Basel) ; 12(10)2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36292231

RESUMO

The purpose of this study was to evaluate the potential of dual-energy CT (DECT) with virtual unenhanced imaging (VNC) and iodine maps (IM) to differentiate between intraperitoneal hematomas (IH) and bowel structures (BS) compared to linearly blended DECT (DE-LB) images (equivalent to single-energy CT). This retrospective study included the DECT of 30 patients (mean age: 64.5 ± 15.1 years, 19 men) with intraperitoneal hematomas and 30 negative controls. VNC, IM, and DE-LB were calculated. Imaging follow-up and surgical reports were used as references. Three readers assessed diagnostic performance and confidence in distinguishing IH and BS for DE-LB, VNC, and IM. Diagnostic confidence was assessed on a five-point Likert scale. The mean values of VNC, IM, and DE-LB were compared with nonparametric tests. Diagnostic accuracy was assessed by calculating receiver operating characteristics (ROC). The results are reported as medians with interquartile ranges. Subjective image analysis showed higher diagnostic performance (sensitivity: 96.7−100% vs. 88.2−96.7%; specificity: 100% vs. 96.7−100%; p < 0.0001; ICC: 0.96−0.99) and confidence (Likert: 5; IRQ [5−5] vs. 4, IRQ [3−4; 4−5]; p < 0.0001; ICC: 0.80−0.96) for DECT compared to DE-LB. On objective image analysis, IM values for DECT showed significant differences between IH (3.9 HU; IQR [1.6, 8.0]) and BS (39.5 HU; IQR [29.2, 43.3]; p ≤ 0.0001). VNC analysis revealed a significantly higher attenuation of hematomas (50.5 HU; IQR [44.4, 59.4]) than BS (26.6 HU; IQR [22.8, 32.4]; p ≤ 0.0001). DE-LB revealed no significant differences between hematomas (60.5 HU, IQR [52.7, 63.9]) and BS (63.9 HU, IQR [58.0, 68.8]; p > 0.05). ROC analysis revealed the highest AUC values and sensitivity for IM (AUC = 100%; threshold by Youden-Index ≤ 19 HU) and VNC (0.93; ≥34.1 HU) compared to DE-LB (0.64; ≤63.8; p < 0.001). DECT is suitable for accurate discrimination between IH and BS by calculating iodine maps and VNC images.

7.
PLoS One ; 17(8): e0269816, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35960722

RESUMO

OBJECTIVES: The study aims to investigate the impact of COVID-19 pandemic on physical activity and frequency of implantable cardioverter-defibrillator (ICD) therapies of patients with cardiac implantable electronic devices. METHODS AND RESULTS: Physical activity, heart rate and ICD-therapies were assessed via routine remote monitoring over two years. We focussed on a 338-day period during COVID-19 pandemic that was divided in 6 time-intervals defined by public health interventions and compared to the previous regular year. Paired nonparametric longitudinal analysis was performed to detect differences between time-intervals. To model effects of age, sex and time we applied a nonparametric ANOVA-type-statistic. 147 patients with cardiac implantable electronic devices were analysed. Longitudinal analysis of physical activity in 2019 and 2020 showed a specific weekly and seasonal pattern. Physical activity was reduced during the pandemic (mean daily physical activity 2019: 12.4% vs. 2020: 11.5%; p<0.0001) with the strongest reductions (fold changes 0.885/0.889, p<0.0001/p<0.0001) during the two lockdown-periods. In older patients (>70 years), physical activity was decreased in every time-interval of the year 2020. In time-intervals of eased restrictions, physical activity of younger patients (≤70 years) was not different compared to 2019. No variation in mean heart rate, arrhythmia-burden and count of ICD-therapies was found. CONCLUSION: Physical activity shows fluctuations dependent on days of the week and time of the year. During the pandemic, physical activity was reduced in patients with cardiac implantable electronic devices with the strongest reductions during lockdown-periods. Younger patients resumed former levels of physical activity in times of eased restrictions while older patients remained less active. Thus, activation of the elderly population is important to prevent long-term health impairments due to the pandemic.


Assuntos
COVID-19 , Desfibriladores Implantáveis , Idoso , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Eletrônica , Exercício Físico , Humanos , Pandemias
8.
Diagn Interv Radiol ; 28(3): 208-216, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35748202

RESUMO

PURPOSE Differentiation of incidental adrenal lesions remains a challenge in diagnostic imaging, especially on single-phase portal venous computed tomography (CT) in the oncological setting. The aim of the study was to explore the ability of dual-energy CT (DECT)-based iodine quantification and virtual non-contrast (VNC) imaging and advanced radiomic analysis of DECT for differentiation of adrenal adenomas from metastases. METHODS A total of 46 patients with 49 adrenal lesions underwent clinically indicated staging DECT and magnetic resonance imaging. Median values of quantitative parameters such as VNC, fat frac- tion, and iodine density in DECT images were collected and compared between adenomas and metastases using non-parametric tests. Magnetic resonance imaging, washout CT, and clinical follow-up were used as a reference standard. Diagnostic accuracy was assessed by calculat- ing receiver operating characteristics. A DECT tumor analysis prototype software was used for semiautomatic segmentation of adrenal lesions and extraction of radiomic features. A radiomics prototype was used to analyze the data with multiple logistic regression and random forest clas- sification to determine the area under the curve (AUC). RESULTS The study cohort (60.87% women; mean age: 66.91 ± 12.93 years) consisted of 32 adenomas and 17 metastases. DECT-based VNC imaging (AUC=0.89) and fat quantification (AUC=0.86) differentiate between adrenal adenomas and metastases with high diagnostic accuracy (P < .001). Analysis of radiomic features revealed that DECT features such as VNC imaging and fat fraction (AUC = 0.87-0.89; < .001) and radiomic features such as 90th percentile and total energy (AUC = 0.88-0.93; P < .001) differentiate with high diagnostic accuracy between adrenal adeno- mas and metastases. Random forest classification revealed an AUC of 0.83 for separating adrenal adenomas from metastases. CONCLUSION Virtual non-contrast imaging and fat quantification as well as extraction of radiomic features accurately differentiate between adrenal adenomas and metastases on single-phase oncologic staging DECT.


Assuntos
Adenoma , Neoplasias das Glândulas Suprarrenais , Iodo , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
9.
Insights Imaging ; 13(1): 48, 2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-35312842

RESUMO

BACKGROUND: Radiofrequency ablation (RFA) is a minimal-invasive, local therapy in patients with circumscribed metastatic disease. Although widely used, long time survival analysis of treated liver metastases is still pending while also analysing the patients' experience of MR-based radiofrequency. METHODS: Monocentric, retrospective analysis of long-time overall and progression free survival (OS; PFS) of 109 patients, treated with MRI-guided hepatic RFA between 1997 and 2010, focusing on colorectal cancer patients (CRC). Complimentary therapies were evaluated and Kaplan Meier-curves were calculated. Patients' experience of RFA was retrospectively assessed in 28 patients. RESULTS: 1-, 3-, 5-, 10-year OS rates of 109 patients with different tumour entities were 83.4%, 53.4%, 31.0% and 22.9%, median 39.2 months, with decreasing survival rates for larger metastases size. For 72 CRC patients 1-, 3-, 5-, 10-year OS rates of 90.2%, 57.1%, 36.1% and 26.5% were documented (median 39.5 months). Thereof, beneficial outcome was detected for patients with prior surgery of the CRC including chemotherapy (median 53.0 months), and for liver metastases up to 19 mm (28.5% after 145 months). Hepatic PFS was significantly higher in patients with liver lesions up to 29 mm compared to larger ones (p = 0.035). 15/28 patients remembered RFA less incriminatory than other applied therapies. CONCLUSIONS: This is the first single-centre, long-time OS and PFS analysis of MRI-guided hepatic RFA of liver metastases from different tumour entities, serving as basis for further comparison studies. Patients' experience of MR based RFA should be analysed simultaneously to the performed RFA in the future.

10.
Rofo ; 194(9): 1012-1019, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35272363

RESUMO

PURPOSE: To investigate reduction of radiation exposure in unenhanced CT in suspicion of renal calculi using a tin-filtered high tube voltage protocol compared to a standard low-dose protocol without spectral shaping. MATERIALS AND METHODS: A phantom study using 7 human renal calculi was performed to test both protocols. 120 consecutive unenhanced CT examinations performed due to suspicion of renal calculi were included in this retrospective, monocentric study. 60 examinations were included with the standard-dose protocol (SP) (100 kV/130 mAs), whereas another 60 studies were included using a low-dose protocol (LD) applying spectral shaping with tin filtration of high tube voltages (Sn150 kV/80 mAs). Image quality was assessed by two radiologists in consensus blinded to technical parameters using an equidistant Likert scale ranging from 1-5 with 5 being the highest score. Quantitative image quality was assessed using regions of interest in abdominal organs, muscles, and adipose tissue to analyze image noise and signal-to-noise ratios (SNR). Commercially available dosimetry software was used to determine and compare effective dose (ED) and size-specific dose estimates (SSDEmean). RESULTS: All seven renal calculi of the phantom could be detected with both protocols. There was no difference regarding calcluli size between the two protocols except for the smallest one. The smallest concretion measured 1.5 mm in LD and 1.0 mm in SP (ground truth 1.5 mm). CTDIvol was 3.36 mGy in LD (DLP: 119.3 mGycm) and 8.27 mGy in SP (DLP: 293.6 mGycm). The mean patient age in SP was 47 ±â€Š17 years and in LD 49 ±â€Š13 years. Ureterolithiasis was found in 33 cases in SP and 32 cases in LD. The median concretion size was 3 mm in SP and 4 mm in LD. The median ED in LD was 1.3 mSv (interquartile range (IQR) 0.3 mSv) compared to 2.3 mSv (IQR 0.9 mSv) in SP (p < 0.001). The SSDEmean of LD was also significantly lower compared to SP with 2.4 mGy (IQR 0.4 mGy) vs. 4.8 mGy (IQR 2.3 mGy) (p < 0.001). The SNR was significantly lower in LD compared to SP (p < 0.001). However, there was no significant difference between SP and LD regarding the qualitative assessment of image quality with a median of 4 (IQR 1) for both groups (p = 0.648). CONCLUSION: Tin-filtered unenhanced abdominal CT for the detection of renal calculi using high tube voltages leads to a significant reduction of radiation exposure and yields high diagnostic image quality without a significant difference compared to the institution's standard of care low-dose protocol without tin filtration. KEY POINTS: · Tin-filtered CT for the detection of renal calculi significantly reduces radiation dose.. · The application of tin filtration provides comparable diagnostic image quality to that of SP protocols.. · An increase in image noise does not hamper diagnostic image quality.. CITATION FORMAT: · Gassenmaier S, Winkelmann MT, Magnus J et al. Low-Dose CT for Renal Calculi Detection Using Spectral Shaping of High Tube Voltage. Fortschr Röntgenstr 2022; 194: 1012 - 1019.


Assuntos
Cálculos Renais , Tomografia Computadorizada por Raios X , Adulto , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Estanho
11.
Rofo ; 194(7): 763-770, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35081651

RESUMO

PURPOSE: Evaluation of machine learning-based fully automated artery-specific coronary artery calcium (CAC) scoring software, using semi-automated software as a reference. METHODS: A total of 505 patients underwent non-contrast-enhanced calcium scoring computed tomography (CSCT). Automated, machine learning-based software quantified the Agatston score (AS), volume score (VS), and mass score (MS) of each coronary artery [right coronary artery (RCA), left main (LM), circumflex (CX) and left anterior descending (LAD)]. Identified CAC of readers who annotated the data with semi-automated software served as a reference standard. Statistics included comparisons of evaluation time, agreement of identified CAC, and comparisons of the AS, VS, and MS of the reference standard and the fully automated algorithm. RESULTS: The machine learning-based software correlated strongly with the reference standard for the AS, VS, and MS (Spearman's rho > 0.969) (p < 0.001), with excellent agreement (ICC > 0.919) (p < 0.001). The mean assessment time of the reference standard was 59 seconds (IQR 39-140) and that of the automated algorithm was 5.9 seconds (IQR 3.9-16) (p < 0.001). The Bland-Altman plots mean difference and 1.96 upper and lower limits of agreement for all arteries combined were: AS 0.996 (1.33 to 0.74), VS 0.995 (1.40 to 0.71), and MS 0.995 (1.35 to 0.74). The mean bias was minimal: 0.964-1.0429. Risk class assignment showed high accuracy for the AS in total (weighed κ = 0.99) and for each individual artery (κ = 0.96-0.99) with corresponding correct risk group assignment in 497 of 505 patients (98.4 %). CONCLUSION: The fully automated artery-specific coronary calcium scoring algorithm is a time-saving procedure and shows excellent correlation and agreement compared with the clinically established semi-automated approach. KEY POINTS: · Very high correlation and agreement between fully automatic and semi-automatic calcium scoring software.. · Less time-consuming than conventional semi-automatic methods.. · Excellent tool for artery-specific calcium scoring in a clinical setting.. CITATION FORMAT: · Winkelmann MT, Jacoby J, Schwemmer C et al. Fully Automated Artery-Specific Calcium Scoring Based on Machine Learning in Low-Dose Computed Tomography Screening. Fortschr Röntgenstr 2022; 194: 763 - 770.


Assuntos
Cálcio , Doença da Artéria Coronariana , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
12.
J Appl Clin Med Phys ; 22(10): 261-269, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34453864

RESUMO

PURPOSE: To evaluate the transient artifact augmentation of microtubes in magnetic resonance imaging by fluid injection. METHODS: Twenty-one fluorinated ethylene propylene catheters (inner diameter 760 µm) were filled with three different contrast media at various concentrations (Ferucarbotran, Resovist®, Bayer Schering Pharma; Manganese dichloride, MnCl2, Sigma-Aldrich; Gadobutrol, Gadovist®, Bayer Schering Pharma). Artifact appearance was determined in an ex vivo phantom at 1.5 T using three different sequences: T1-weighted three-dimensional volume interpolated breath-hold examination, T2-weighted turbo spin echo, and T1-weighted fast low angle shot. Catheter angulation to the main magnetic field (B0) was varied. Influence of parameters on artifact diameters was assessed with a multiple linear regression similar to an analysis of variance. RESULTS: Artifact diameter was significantly influenced by the contrast agent (p < 0.001), concentration of the contrast agent (p < 0.001), angulation of the phantom to B0 with the largest artifact at 90° (p < 0.001), and encoding direction with a larger diameter in phase encoding direction (PED, p < 0.001). Mean artifact diameters at 90° angulation to B0 in PED were 18.5 ± 5.4 mm in 0.5 mmol/ml Ferucarbotran, 8.7 ± 2.5 mm in 1 mmol/ml Gadobutrol, and 11.6 ± 4.6 mm in 5 mmol/ml MnCl2 . CONCLUSIONS: Fluid-based contrast agents might be applied to interventional devices and thus temporarily augment the artifact ensuring both visibility and safe navigation.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Meios de Contraste , Humanos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
13.
Diagnostics (Basel) ; 11(7)2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34359338

RESUMO

(1) Background: To evaluate the diagnostic performance of a simulated ultra-low-dose (ULD), high-pitch computed tomography pulmonary angiography (CTPA) protocol with low tube current (mAs) and reduced scan range for detection of pulmonary embolisms (PE). (2) Methods: We retrospectively included 130 consecutive patients (64 ± 16 years, 69 female) who underwent clinically indicated high-pitch CTPA examination for suspected acute PE on a 3rd generation dual-source CT scanner (SOMATOM FORCE, Siemens Healthineers, Forchheim, Germany). ULD datasets with a realistic simulation of 25% mAs, reduced scan range (aortic arch-basal pericardium), and Advanced Modeled Iterative Reconstruction (ADMIRE®, Siemens Healthineers, Forchheim, Germany) strength 5 were created. The effective radiation dose (ED) of both datasets (standard and ULD) was estimated using a dedicated dosimetry software solution. Subjective image quality and diagnostic confidence were evaluated independently by three reviewers using a 5-point Likert scale. Objective image quality was compared using noise measurements. For assessment of diagnostic accuracy, patients and pulmonary vessels were reviewed binarily for affection by PE, using standard CTPA protocol datasets as the reference standard. Percentual affection of pulmonary vessels by PE was computed for disease severity (modified Qanadli score). (3) Results: Mean ED in ULD protocol was 0.7 ± 0.3 mSv (16% of standard protocol: 4.3 ± 1.7 mSv, p < 0.001, r > 0.5). Comparing ULD to standard protocol, subjective image quality and diagnostic confidence were comparably good (p = 0.486, r > 0.5) and image noise was significantly lower in ULD (p < 0.001, r > 0.5). A total of 42 patients (32.2%) were affected by PE. ULD protocol had a segment-based false-negative rate of only 0.1%. Sensitivity for detection of any PE was 98.9% (95% CI, 97.2-99.7%), specificity was 100% (95% CI, 99.8-100%), and overall accuracy was 99.9% (95% CI, 98.6-100%). Diagnoses correlated strongly between ULD and standard protocol (Chi-square (1) = 42, p < 0.001) with a decrease in disease severity of only 0.48% (T = 1.667, p = 0.103). (4) Conclusions: Compared to a standard CTPA protocol, the proposed ULD protocol proved reliable in detecting and ruling out acute PE with good levels of image quality and diagnostic confidence, as well as significantly lower image noise, at 0.7 ± 0.3 mSv (84% dose reduction).

14.
Funct Plant Biol ; 48(7): 732-742, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34099101

RESUMO

The distributions of CAM and C3 epiphytic bromeliads across an altitudinal gradient in western Panama were identified from carbon isotope (δ13C) signals, and epiphyte water balance was investigated via oxygen isotopes (δ18O) across wet and dry seasons. There were significant seasonal differences in leaf water (δ18Olw), precipitation, stored 'tank' water and water vapour. Values of δ18Olw were evaporatively enriched at low altitude in the dry season for the C3 epiphytes, associated with low relative humidity (RH) during the day. Crassulacean acid metabolism (CAM) δ18Olw values were relatively depleted, consistent with water vapour uptake during gas exchange under high RH at night. At high altitude, cloudforest locations, C3 δ18Olw also reflected water vapour uptake by day. A mesocosm experiment with Tillandsia fasciculata (CAM) and Werauhia sanguinolenta (C3) was combined with simulations using a non-steady-state oxygen isotope leaf water model. For both C3 and CAM bromeliads, δ18Olw became progressively depleted under saturating water vapour by day and night, although evaporative enrichment was restored in the C3 W. sanguinolenta under low humidity by day. Source water in the overlapping leaf base 'tank' was also modified by evaporative δ18O exchanges. The results demonstrate how stable isotopes in leaf water provide insights for atmospheric water vapour exchanges for both C3 and CAM systems.


Assuntos
Vapor , Água , Isótopos de Oxigênio , Panamá , Folhas de Planta
15.
Diagnostics (Basel) ; 11(1)2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33450942

RESUMO

To evaluate the effect of radiation dose reduction on image quality and diagnostic confidence in contrast-enhanced whole-body computed tomography (WBCT) staging. We randomly selected March 2016 for retrospective inclusion of 18 consecutive patients (14 female, 60 ± 15 years) with clinically indicated WBCT staging on the same 3rd generation dual-source CT. Using low-dose simulations, we created data sets with 100, 80, 60, 40, and 20% of the original radiation dose. Each set was reconstructed using filtered back projection (FBP) and Advanced Modeled Iterative Reconstruction (ADMIRE®, Siemens Healthineers, Forchheim, Germany) strength 1-5, resulting in 540 datasets total. ADMIRE 2 was the reference standard for intraindividual comparison. The effective radiation dose was calculated using commercially available software. For comparison of objective image quality, noise assessments of subcutaneous adipose tissue regions were performed automatically using the software. Three radiologists blinded to the study evaluated image quality and diagnostic confidence independently on an equidistant 5-point Likert scale (1 = poor to 5 = excellent). At 100%, the effective radiation dose in our population was 13.3 ± 9.1 mSv. At 20% radiation dose, it was possible to obtain comparably low noise levels when using ADMIRE 5 (p = 1.000, r = 0.29). We identified ADMIRE 3 at 40% radiation dose (5.3 ± 3.6 mSv) as the lowest achievable radiation dose with image quality and diagnostic confidence equal to our reference standard (p = 1.000, r > 0.4). The inter-rater agreement for this result was almost perfect (ICC ≥ 0.958, 95% CI 0.909-0.983). On a 3rd generation scanner, it is feasible to maintain good subjective image quality, diagnostic confidence, and image noise in single-energy WBCT staging at dose levels as low as 40% of the original dose (5.3 ± 3.6 mSv), when using ADMIRE 3.

16.
Eur J Radiol ; 134: 109426, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33254062

RESUMO

PURPOSE: To evaluate the effects of radiation dose reduction on diagnostic accuracy and image quality of pulmonary angiography CT (CTPA) in adults with suspected pulmonary embolism (PE). MATERIAL & METHODS: 52 consecutive patients received CTPA for suspected PE. Realistic low-Dose CT simulations were generated using an offline software (ReconCT, Siemens Healthineers, Forchheim, Germany), as either filter back projections (FBP) or iterative reconstruction as ADMIRE (strength 3 or 5) with 25 %, 50 % and 75 % of the original dose. To assess image quality (overall image quality, noise, artifacts, and sharpness) and diagnostic confidence, a five-point scale was used. Patient-based and segment-based diagnostic accuracy was calculated for Low-dose computed tomography (LDCT)-reconstruction with original dose CTPA as a standard of reference. Furthermore, effective radiation doses were calculated using a commercially available dose management platform (Radimetrics, Bayer HealthCare, Leverkusen, Germany). RESULTS: Among 52 patients, a total of 15 patients (28.8 %) had acute pulmonary artery embolism. The median dose-length product and effective dose for all 52 scans were 291.1 ±â€¯210.1 mGy⋅cm and 5.8 ±â€¯3.4 mSv. Overall subjective image quality was highest for ADMIRE 5 with 75 % and lowest for FBP with 25 % of the original dose (median [interquartile range]:5 [5] vs. 3 [2-3], p < 0.001. Patient-based diagnostic accuracy was perfect for all iteratively reconstructed data sets (ADMIRE 3 and 5) (sensitivity: 100 %, negative predictive value [NPV]: 100 %). LDCT data sets with FBP had perfect diagnostic accuracy at 50 % and 75 % of the original dose, which however decreased at 25 % of the original dose (sensitivity: 93 %; [NPV]: 97 %). Segment-based diagnostic accuracy was high for ADMIRE 3 and 5 down to 25 % dose reduction (sensitivity: 90.4 % specificity: 99.5 %) and lowest for FBP with 25 % dose reduction (sensitivity: 84.6 %, specificity: 98.9 %). Inter-class correlation regarding the detection of PE was almost perfect at all doses and recons (ICC: 96.1-1.0). Thus, accurate diagnosis for PE was possible for ADMIRE 3 and 5 datasets with 25 % of the original dose (1.45 mSv) and for FBP with 50 % of the original dose (2.9 mSv). CONCLUSION: Our findings indicate that radiation dose reduction down to 25 % (1.45 mSv) of the original data via iterative reconstruction algorithms on a 3rd generation Dual Source CT (DSCT) scanner maintained the diagnostic accuracy and image quality for the assessment of PE in CTPA.


Assuntos
Angiografia , Redução da Medicação , Adulto , Algoritmos , Alemanha , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X
17.
J Shoulder Elbow Surg ; 30(1): 194-199, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32807372

RESUMO

PURPOSE: Range of motion adaptations in the shoulders of overhead throwing athletes have been reported, but knowledge about the development of soft-tissue adaptations is limited. The purpose of this study was to investigate differences in posterior shoulder capsule thickness and internal rotation between the throwing and non-throwing shoulder. METHODS: On the basis of the sample size calculation, we assessed 63 youth elite handball players (33 boys and 30 girls, mean age: 13.6 ± 0.9 years) for glenohumeral internal and external rotational range of motion, humeral retrotorsion, and posterior capsule thickness (PCT) with a manual goniometer and a portable ultrasound device and calculated sports-specific differences between the throwing and non-throwing shoulder as well as correlations with PCT. RESULTS: Youth handball players showed side-to-side differences in internal rotation, external rotation, and humeral retrotorsion between the throwing and non-throwing shoulder. Posterior shoulder capsules were 1.21 times thicker (95% confidence interval: 1.1-1.3) in the throwing shoulder than in the non-throwing shoulder (1.3 ± 0.3 mm vs. 1.2 ± 0.2 mm, P < .0001). Loss of internal rotation did not correlate with PCT. CONCLUSIONS: In youth elite handball athletes, posterior shoulder tightness and subsequent sports-specific loss of internal rotation in the throwing shoulder are not related to PCT. Thus, in this age class, other (soft-tissue) factors must be responsible for this condition.


Assuntos
Traumatismos em Atletas/diagnóstico por imagem , Cápsula Articular/diagnóstico por imagem , Articulação do Ombro , Adaptação Fisiológica , Adolescente , Artrometria Articular , Traumatismos em Atletas/patologia , Criança , Estudos Transversais , Transtornos Traumáticos Cumulativos/diagnóstico por imagem , Transtornos Traumáticos Cumulativos/patologia , Feminino , Humanos , Cápsula Articular/patologia , Masculino , Amplitude de Movimento Articular , Rotação , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/patologia , Ultrassonografia
18.
Diagnostics (Basel) ; 10(12)2020 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-33322074

RESUMO

The aim of this study was to investigate the effects of dose reduction on diagnostic accuracy and image quality of cervical computed tomography (CT) in patients with suspected cervical abscess. Forty-eight patients (mean age 45.5 years) received a CT for suspected cervical abscess. Low-dose CT (LDCT) datasets with 25%, 50%, and 75% of the original dose were generated with a realistic simulation. The image data were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) (strengths 3 and 5). A five-point Likert scale was used to assess subjective image quality and diagnostic confidence. The signal-to-noise ratio (SNR) of the sternocleidomastoid muscle and submandibular gland and the contrast-to-noise ratio (CNR) of the sternocleidomastoid muscle and submandibular glandular fat were calculated to assess the objective image quality. Diagnostic accuracy was calculated for LDCT using the original dose as the reference standard. The prevalence of cervical abscesses was high (72.9%) in the cohort; the mean effective dose for all 48 scans was 1.8 ± 0.8 mSv. Sternocleidomastoid and submandibular SNR and sternocleidomastoid muscle fat and submandibular gland fat CNR increased with higher doses and were significantly higher for ADMIRE compared to FBP, with the best results in ADMIRE 5 (all p < 0.001). Subjective image quality was highest for ADMIRE 5 at 75% and lowest for FBP at 25% of the original dose (p < 0.001). Diagnostic confidence was highest for ADMIRE 5 at 75% and lowest for FBP at 25% (p < 0.001). Patient-based diagnostic accuracy was high for all LDCT datasets, down to 25% for ADMIRE 3 and 5 (sensitivity: 100%; specificity: 100%) and lower for FBP at 25% dose reduction (sensitivity: 88.6-94.3%; specificity: 92.3-100%). The use of a modern dual-source CT of the third generation and iterative reconstruction allows a reduction in the radiation dose to 25% (0.5 mSv) of the original dose with the same diagnostic accuracy for the assessment of neck abscesses.

19.
Sci Adv ; 6(46)2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33177094

RESUMO

Approximately one-third of the Earth's photosynthetic CO2 assimilation occurs in a pyrenoid, an organelle containing the CO2-fixing enzyme Rubisco. How constituent proteins are recruited to the pyrenoid and how the organelle's subcompartments-membrane tubules, a surrounding phase-separated Rubisco matrix, and a peripheral starch sheath-are held together is unknown. Using the model alga Chlamydomonas reinhardtii, we found that pyrenoid proteins share a sequence motif. We show that the motif is necessary and sufficient to target proteins to the pyrenoid and that the motif binds to Rubisco, suggesting a mechanism for targeting. The presence of the Rubisco-binding motif on proteins that localize to the tubules and on proteins that localize to the matrix-starch sheath interface suggests that the motif holds the pyrenoid's three subcompartments together. Our findings advance our understanding of pyrenoid biogenesis and illustrate how a single protein motif can underlie the architecture of a complex multilayered phase-separated organelle.

20.
Nat Plants ; 6(12): 1480-1490, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33230314

RESUMO

Approximately one-third of global CO2 fixation occurs in a phase-separated algal organelle called the pyrenoid. The existing data suggest that the pyrenoid forms by the phase separation of the CO2-fixing enzyme Rubisco with a linker protein; however, the molecular interactions underlying this phase separation remain unknown. Here we present the structural basis of the interactions between Rubisco and its intrinsically disordered linker protein Essential Pyrenoid Component 1 (EPYC1) in the model alga Chlamydomonas reinhardtii. We find that EPYC1 consists of five evenly spaced Rubisco-binding regions that share sequence similarity. Single-particle cryo-electron microscopy of these regions in complex with Rubisco indicates that each Rubisco holoenzyme has eight binding sites for EPYC1, one on each Rubisco small subunit. Interface mutations disrupt binding, phase separation and pyrenoid formation. Cryo-electron tomography supports a model in which EPYC1 and Rubisco form a codependent multivalent network of specific low-affinity bonds, giving the matrix liquid-like properties. Our results advance the structural and functional understanding of the phase separation underlying the pyrenoid, an organelle that plays a fundamental role in the global carbon cycle.


Assuntos
Chlamydomonas reinhardtii/química , Chlamydomonas reinhardtii/metabolismo , Estrutura Molecular , Fotossíntese/fisiologia , Ribulose-Bifosfato Carboxilase/química , Ribulose-Bifosfato Carboxilase/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...